Technical specification | ||||||||
---|---|---|---|---|---|---|---|---|
Dimensions | Stage size | 12×10 m | 39,40×32,80 ft | |||||
A | Internal width | 12,30 m | 40.35 ft | |||||
B | Overall external width | 14,64 m | 48.03 ft | |||||
C | Internal depth | 10,60 m | 34.78 ft | |||||
D | Overall external depth | 12,99 m | 42.62 ft | |||||
E | Clearance | 7,12 m | 23.36 ft | |||||
F | Overall height | 9,43 m | 30.94 ft | |||||
G | PA wing – internal width | 3,15 m | 10.33 ft | |||||
H | PA wing -Overall external width | 3,44 m | 11.29 ft |
Loading capacity | ||||||||
---|---|---|---|---|---|---|---|---|
Loading capacity | Stage size | 12×10 m | 39,40×32,80 ft | |||||
Main grid | Uniformly distributed (UDL) | 3480 Kg | 7665 lbs | |||||
Point loads 8x400kg + UDL total | 4600 Kg | 10 132 lbs | ||||||
PA wing | Central Point load (CPL) | 1500 Kg | 3304 lbs | – Kg | – lbs | – Kg | – lbs | |
Cantilever | Point load (CPL) | – Kg | – lbs | 150 Kg | 330.4 lbs | 150 Kg | 330 lbs | |
* See structural report for exact load positioning |
Operational specifications | ||||||
---|---|---|---|---|---|---|
Design standarts | DIN EN 13814 (2005) DIN 1055-4 DIN 4113 DIN 18800 | Fairground and amusement park machinery and structures Actions on structures / wind Design of aluminium structures Design of steel structures | ||||
• All our structures are standard produced under EN 1090 EXC2, include neccessary guy wires, instruction manual and engineering report | ||||||
Wind management | Out of service In service | 29,6m/s – 106km/h-66mph (Max. gust windspeed) 17,8m/s – 64km/h – 40mph (Max. gust windspeed) | ||||
* Calculations based on 100% closed side canopies * Side canopies to be removed above this wind speed if not considered | ||||||
Ballast | This can vary per tower from 200kg / 440lbs up to 5300kg / 11674lbs and depends on: • If tower bases are interconnected or free-standing • Layout of canopies • Self-weight of load or interconnected stage is considered (Might be deducted from ballast under certain conditions) • Friction material used between screw jacks, padding and sub soil | |||||
Canopy & sidewalls | B1 fire retardant canopy on request, single piece format or kedder profiles Silvergrey; other colors or inside black on request B1 fire retardant side nets in compliance with latest Eurocodes | |||||
Customized | Customisation (i.e. truss configuration, alternative dimensions, roof adjustability) on requirement |